Home » Shop » hot sale » Absolute Process Instruments API 7010 G _ Frequency to DC

Absolute Process Instruments API 7010 G _ Frequency to DC

Original price was: $319.20.Current price is: $244.66.

Sale!

21 in stock

SKU: API 7010 G Category:

Absolute Process Instruments API 7010 G _ Frequency to DC

Features:

  • Precision Frequency to DC Converter
  • Plug In Design for Faster Installation
  • Full 2000 V Input/Output/Power Isolation
  • Input and Output LoopTracker® LEDs
  • Functional Test Button
  • Built-In Loop Power Supply for Output

Applications:

  • Monitor and Control Motor or Line Speed
  • Convert Speed and Frequency Signals
  • Simplify Interfacing of Frequency Sensors

The API 7010 G accepts a frequency input and provides an optically isolated DC voltage or current analog output that is linearly proportional to the input.

The full 3-way (input, output, power) isolation between input and output makes this module useful for ground loop elimination, common mode signal rejection or noise pickup reduction.

Also standard on the API 7010 G is an 18 VDC input excitation supply. If needed, this supply can be used to power a passive sensor, eliminating the need for an additional external power supply.

Common applications include frequency to DC conversions from frequency output type devices such as rotary encoders, magnetic pick-ups, variable speed drives and flow meters. The API 7010 G can also be used to convert a PLC pulse rate output to a proportional analog signal.

Output Loop Power Supply

Standard on the API 7010 G is an 20 VDC loop excitation supply. This supply can be used to power passive input devices, often eliminating the need for an additional external power supply.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Output Test

An API exclusive feature includes the test button to provide a fixed output (independent of the input) when held depressed. The test output level is potentiometer adjustable 100% of the output span. The output test button greatly aids in saving time during initial startup and/or troubleshooting.

Specifications Table:

Frequency Input Range Factory configured, please specify input range

  • Frequency: 0-25 Hz to 0-20 kHz
  • 5 µsec minimum pulse, 100 mV minimum amplitude change
Input Amplitude Range 100 mV to 150 VRMS
Input Impedance (Voltage Input)
  • 10 kW nominal (maximum sensitivity)
  • 100 kW nominal (minimum sensitivity)
Input Sensitivity/Hysteresis Single turn potentiometer for sensitivity adjustment

  • Maximum sensitivity: ±25 mV typical
  • Minimum sensitivity: ±2.5 V typical
Input Protection
  • Normal mode: 200% of input rating
  • Common mode: 600 VDC or 600 VACp input to ground

System voltages must not exceed socket voltage rating

Input Power Supply 18 VDC ±10%, unregulated, 25 mADC, max. ripple, <1.5 VP-P (may be used to power sensor)
DC Output Range Factory configured, please specify output range.

  • Voltage: 0-1 VDC to 0-10 VDC
  • Bipolar voltage: ±1 VDC to ±10 VDC
  • Current: 0-2 mADC to 0-20 mADC, 20 V compliance, 1000 Ω at 20 mA
Output Calibration Multi-turn zero and span potentiometers (±15% of adjustment range typical)
Output Loop Power Supply 20 VDC nominal, regulated, 25 mADC, max. ripple <10 mVRMS
Output Test Button sets output to test level when pressed (factory set to approximately 50% of span)
Output Ripple and Noise Less than 10 mVRMS
Linearity Better than ±0.3% of span
Response Time 70 milliseconds typical
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability, calculated, not tested
Isolation
  • 2000 VRMS minimum
  • Full isolation: power to input, power to output, input to output
Installation Environment
  • IP 40, requires installation in panel or enclosure
  • Use with API 008 or API 008 FS socket
  • Socket mounts to 35 mm DIN rail or can be surface mounted UL 508C pollution degree 2 environments or better
Power 115 VAC ±10%, 50/60 Hz, 2.5 W max.